- Indirect Food Contact Meets requirements for indirect food contact
- LEED v4 Low-Emitting SCAQMD Method 304-91
- Low VOC Per product data sheet
- ASTM Tested Full test data on the TDS
- Family-Run Since 2004 20+ years in the trade
Premera Easy MVB Moisture Vapor Barrier Primer
Premera Easy MVB is a single-component moisture vapor barrier primer, a water-based coat that reacts with the free calcium hydrates in bare concrete to form an insoluble barrier from the inside. It is built for installers who need to stop rising slab moisture before epoxy, so a coating bonds and stays down instead of blistering or pushing efflorescence through the finished floor.
Built to stop slab moisture
Technical specifications
| MOISTURE PROTECTION | |
| Hydrostatic pressure | Blocks up to 25 lb |
| Moisture emission | Under 3 lb per 1,000 sq ft over 24 hours |
| Efflorescence | Blocked |
| COMPOSITION | |
| Chemistry | Single component, water-based, no mixing, no pot life |
| Solids by volume | 10% |
| VOC | Zero |
| COVERAGE AND APPLICATION | |
| Coverage | 100 to 250 sq ft per gallon, broom finish lower, burnished higher |
| Application | Spray two coats wet-on-wet at 3 to 4 mils, 50% overlap, to saturation |
| Substrates | Bare concrete, brick, mortar, tile |
| CURE AND RECOAT | |
| Tack-free | 4 hours |
| Post-cure | 24 hours |
| Recoat | Within 24 hours no sanding, after 24 hours sand to dull |
| Cautions | May etch glass and dull aluminum. Not for acid-contaminated surfaces |
Pairs with
Prime under Premera FP1 Fusion Primer and your epoxy or topcoat, or run it ahead of a polishing job. Always confirm the slab with a calcium chloride or RH moisture test first, since Easy MVB is rated to bring emission under 3 lb per 1,000 sq ft.
Ordering
Ships free in the US. Add it to the cart, then add FP1 primer or a T2 topcoat in a click. Running a large job or need contractor pricing? Message your Latux rep and we will set you up.
Formulated for professional installers and supported by Latux.
Frequently Asked Questions
What does Easy MVB do?
It reacts with the free calcium hydrates in bare concrete to form an insoluble internal barrier against rising slab moisture.
How much moisture can it handle?
It blocks up to 25 lb hydrostatic pressure and brings moisture emission under 3 lb per 1,000 sq ft over 24 hours.
How is it applied?
Spray two coats wet-on-wet at 3 to 4 mils with 50% overlap to saturation. It is single component with no mixing and no pot life.
When can I recoat?
Within 24 hours with no sanding. Past 24 hours, sand the surface to dull for a mechanical grip.
What surfaces does it work on?
Bare concrete, brick, mortar, and tile. It may etch glass and dull aluminum, and it is not for acid-contaminated surfaces.
Do I still need a moisture test?
Yes. Confirm the slab with a calcium chloride or RH moisture test first, since it is rated to bring emission under 3 lb per 1,000 sq ft.