At a glance
- SKU
- POLYFLOW-285
- Vendor
- Everflow
- Type
- UV-Stable Polyurea
- Color
- Clear Only
- Recoat
- 2 to 4 hrs
- Coverage
- About 400 sq ft per 2-gal kit
- Working time
- 15 to 20 min at 70°F
- Weight
- 19.6 lb
Everflow EF-285
EF-285 is Everflow's solvent-based aliphatic polyurea coating, a UV-stable primer and base coat in one that bonds to diamond-ground concrete and resists yellowing and chalking. Latux stocks it in clear at 85 percent solids, and it primes and protects in a single fast-curing coat while meeting CFIA and USDA requirements for indirect food contact at under 50 g/L VOC.
Big job or contractor pricing? Request a quote
- Free UPS Ground on orders $150+, or free pickup in Pompano Beach, FL
- Free replacement if your order arrives damaged or we ship the wrong item. Let us know within 48 hours of delivery with photos. Replacement Policy
New customer? Get 10% off your first order
- CFIA / USDA Indirect Food Contact Meets CFIA and USDA requirements for indirect food contact
- LEED v4 Low-Emitting SCAQMD Method 304-91
- Low VOC (<50 g/L) Low VOC (<50 g/L)
- ASTM Tested Full test data on the TDS
- Family-Run Since 2004 20+ years in the trade
Everflow EF-285
EF-285 is Everflow's solvent-based aliphatic polyurea coating, a UV-stable primer and base coat in one that bonds directly to diamond-ground concrete and resists yellowing and chalking. Latux stocks it in clear, and it primes and protects in a single fast-curing coat for professional installers on limited-downtime jobs.
Sold for years as MPC-285. Same polyurea, new name on the pail.
UV-stable primer and base coat built for prepared concrete

Which topcoat do you need?
| TOPCOAT | EF-275 | EF-280 | EF-285 (this product) | EF-290 | EF-301 |
| Solids | 75% | 80% | 85% | 90% | 85% |
| Finish and gloss | High-gloss clear, 89.5 GU | High-gloss clear, 89.5 GU | High-gloss clear, 89.5 GU | High-gloss clear, 89.5 GU | Satin, 35 GU |
| Coverage per kit | About 400 sq ft over coating, 2-gal kit | About 600 sq ft over coating, 3-gal kit | About 400 sq ft at 8 mils, 2-gal kit | About 400 sq ft over coating, 2-gal kit | 350 to 450 sq ft, 1-gal kit |
| Recoat window | 2 to 4 hr | 2 to 4 hr | 2 to 4 hr | 2 to 4 hr | Applied as the final coat |
| Foot traffic | 4 to 8 hr | 4 to 8 hr | 4 to 8 hr | 3 to 6 hr | About 1 day |
| UV stability | UV stable, non-yellowing | UV stable, non-yellowing | UV stable, non-yellowing | UV stable, non-yellowing | UV stable, non-yellowing |
| Best for | Fast, budget-friendly clear over flake and color floors | All-around kit with the most coverage per kit | VOC-strict states, under 50 g/L, and UV-stable priming or base coats | Thickest clear coat, fewest coats | Satin-capable final finish that hides scuffs |
Coverage and cure.
Per 2-gallon kit. Real coverage depends on concrete porosity and the profile of the slab.
Cure at 68°F
Working time 15 to 20 min at 70°FWarmer temperatures speed this up; cooler temperatures slow it down.
PHYSICAL AND CHEMISTRY
| Type | Solvent-based aliphatic polyurea, 2-component |
| Solids | 85% by weight |
| Finish and gloss | High-gloss, 89.5 GU at 60 degrees |
| Color | Clear only |
| Viscosity | Part A 300 to 400 cps, Part B 100 to 150 cps |
MECHANICAL
| Abrasion (Taber CS-17) | 0.3 g loss (ASTM D4060) |
| Elongation at break | 40% (ASTM D638) |
| Tensile strength | 5,150 psi (ASTM D638) |
| Pull-off adhesion | Over 363 psi, substrate failure (ASTM D7234) |
| Hardness | Koenig pendulum 175 sec at 8 mils (ASTM D4366) |
| Slip resistance (DCOF) | About 0.75 wet (ASTM E303-93) |
APPLICATION AND CURE
| Working time | 15 to 20 min at 70 degrees F, 50% RH |
| Cure at 68 degrees F | Recoat 2 to 4 hr, foot 4 to 8 hr, vehicle about 1 day, full about 7 days |
| Coverage | 8 mils, about 400 sq ft per 2-gallon kit |
| Surface prep | Diamond grind concrete to ICRI CSP-2 with a moisture barrier |
| Application | 10 mm roller or squeegee, or within a coating system |
| Apply temperature | 41 to 86 degrees F |
COMPLIANCE
| VOC | Under 50 g/L (LEED v4 low-emitting, SCAQMD 304-91) |
| Food contact | Meets CFIA and USDA requirements for indirect food contact |
| Shelf life | 1 year unopened, store 59 to 86 degrees F |
Build the complete system.
What comes in the box, and what goes under and over it. Add any step to your cart from here.
In the kit
- 2-gallon kit: 3.78 L resin (Part A) plus 3.78 L hardener (Part B)
- Two-component system, mix only what you can spread in 15 to 20 minutes
- Supplied clear, this kit is not pre-tinted and Latux does not stock color packs for it
Pairs with
Use EF-285 as the UV-stable primer and base coat under an Everflow polyaspartic or epoxy floor. Diamond grind concrete to ICRI CSP-2, prime with a moisture barrier such as EF-160 on damp slabs, then build your coating system on top.
What is EF-285 and what's it for?
It's a UV-stable, fast-curing aliphatic polyurea coating that works as a primer and base coat. Latux stocks it in clear, so use it as a UV-stable primer and base coat on prepared concrete or as a clear coat inside a multi-coat floor system.
Is EF-285 a polyaspartic or a polyurea?
It's an aliphatic polyurea, part of the same high-performance, UV-stable family. It won't yellow or chalk and provides superior abrasion, chemical, and UV resistance.
What color does it come in?
Clear. Latux sells EF-285 as a clear kit only. We do not stock pre-tinted versions or color packs for it. If the job needs a colored base coat, ask your Latux rep which system fits.
Can I apply EF-285 directly on concrete?
Yes, unlike the clear topcoats EF-275 and EF-280, EF-285 is designed to bond to prepared concrete. Diamond-grind to an ICRI CSP-2 profile and ensure the slab has a moisture barrier to prevent delamination.
How fast does it cure?
At 68°F you can recoat in 2 to 4 hours, return foot traffic in 4 to 8 hours, and vehicle traffic in about a day, with full cure in roughly 7 days.
How much does one kit cover?
A 2-gallon kit covers about 400 sq ft at 8 mils.
How is EF-285 different from EF-275 and EF-280?
EF-285 is a clear polyurea primer and base coat that bonds directly to prepared concrete. EF-275 and EF-280 are clear polyaspartic topcoats applied over a finished base, not on bare concrete.
Why does my coating show tire marks?
Rubber tires can stain these coatings through plasticizer migration, and quick stops or starts can leave rubber burn marks. Use mats under parked vehicles where staining is a concern.